USER’S MANUAL
Heat (Energy)
Recovery Ventilator
Vents Frigate HRV 120 S
Vents Frigate ERV 120 S
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - Recovery Ventilator

USER’S MANUALHeat (Energy) Recovery Ventilator Vents Frigate HRV 120 SVents Frigate ERV 120 S

Page 2

10Frigate HRV(ERV) 120 SUNIT CONTROL The unit is controlled by a three-position speed switch that enables low-speed modes «Low» and «Med» as well as

Page 3

11 The control panel has the following buttons: 1. On/o button; 2. Not active; 3. Fan speed control adjustment (auto/high/med/low);4. Not active

Page 4

12Frigate HRV(ERV) 120 SFig. 9. CO2 transmitter 3. Humidistat The humidistat (g. 10) is used for indoor humidity control. If the indoor humidity

Page 5 - Vents Frigate ERV 120 S

134. Mechanical timer The remote mechanical timer (g. 11) is designed for installation in pollutable areas. As the timer is activated the unit is

Page 6

14Frigate HRV(ERV) 120 S Connect all the above external controls in compliance with the wiring diagram in g. 13. The terminals (2) and (11) are des

Page 7

15SERVICING AND MAINTENANCE Servicing of the unit is required 3-4 times per year. Besides general cleaning, the following operations are required:

Page 8

16Frigate HRV(ERV) 120 STROUBLESHOOTING Problem Possible reasons Solving The fan(s) do(es) not start running. Power supply is o.Make sure the power

Page 9 - SetupofMed

17MANUFACTURER’S WARRANTY Manufacturer hereby guarantees normal performance of the unit within 2 years since the date of its sale in accordance to t

Page 10 - Frigate HRV(ERV) 120 S

18Frigate HRV(ERV) 120 S This is to certify that the heat (energy) recovery ventilator VENTS Frigate HRV(ERV) 120 S has been connected to power mains

Page 12

2Frigate HRV(ERV) 120 SIntroduction ...Application ...

Page 14

3INTRODUCTION APPLICATION DELIVERY SET The unit with heat (energy) recovery is designed to save thermal energy by means of heat and energy recovery

Page 15

4Frigate HRV(ERV) 120 SUnit type HRV - Heat Recovery Ventilator ERV - Energy Recovery Ventilator (enthalpy)Air capacity [CFM]Frigate HRV(ERV) 120

Page 16

5Temperature [º С] -22º F...140º F (-30...+60 º С )Relative humidity [%] 80%Service life Warranty service life is 2 years Operating service life is 5

Page 17

6Frigate HRV(ERV) 120 SSTRUCTURE AND OPERATING LOGICDo not! • Do not operate the unit beyond the specied temperature range or in an aggressive and e

Page 18

7MOUNTING AND SETTINGUP1. Supply fan with backward curved blades and maintenance-free motor with external rotor and integrated thermal protection.2.

Page 19

8Frigate HRV(ERV) 120 SCONDENSATE DRAINAGEFig. 4. Wall unit mounting The Vents Frigate HRV 120 S unit is equipped with a condensate drain hose for c

Page 20

9CONNECTION TO POWER MAINS Cut power supply o before any operations with the unit. The unit shall be connected to power mains by a duly qualied el